Advertisement

Advertisement

Voice/Data/Video Product Focus

Jun 15, 2001
generic image

Advertisement

Advertisement

Advertisement

Advertisement

Advertisement

You're reading an older article from ELECTRICAL CONTRACTOR. Some content, such as code-related information, may be outdated. Visit our homepage to view the most up-to-date articles.

Intermediate Arrester This Ohio Brass arrester is an equivalent substitute to the PVI-LP and PVI polymer intermediate arresters. The main features of this new design includes its very slim silhouette and reduced weight. These features make the arrester ideal for use in enclosures. PVIA arresters fully comply with the ANSI requirements for intermediate arresters. The PVIA arresters are available in MCOV ratings from 2.55 to 57kV, which translates to 3 to 72kV rated voltages. Direct Info Number 264. UPS The UPS R1500 XR from Compaq is a high power density uninterruptible power system , designed to provide power protection in space-constrained rack enterprise environmets. It provides up to 33% more true power, measured in watts, than other units with a similar VA rating. Rated up to 1,500VA/1,340W, the UPS features a unique design and an easy-to-configure front-panel display. It has the capability to manage up to two optional extended runtime battery modules. Direct Info Number 265. Surge Protection Device The SES 200 Series is the newest addition to Erico’s line of Critec surge protection devices. The SES 200 provides a diagnostics panel, which allows users to monitor the operating status of protection for all equipment—ensuring continued protection. The SES 200 is available for 120/240V, 120/208, 220/280, and 277/480V systems. Direct Info Number 266. Surge Suppression Systems Joslyn TransEnd is designed to protect facilities and equipment against lightning damage and surge-induced degradation. These compact but robust MOV-based protectors are available in low-voltage AC configurations with surge current capacities ranging from 25KA to 100KA per mode. The components are bolted to copper bus bars, lowering system impedance and clamping voltage and increasing reliability. Direct Info Number 267. Power Supplies Sola/Hevi-Duty has designated two power supplies specifically for DeviceNet applications. The SDN-24-100 and the SDN8-24-100REDA both feature a rugged metal case and DIN connectors and indefinite short-circuit, overvoltage, and over-temperature protection. Their narrow width makes them easy to mount on a DIN rail. They feature a user-friendly front panel with large, rugged multiple connection screw terminations which are easily accessible and easy to wire and connect. Direct Info Number 268. Power Module The Bussmann power module takes the confusion and headaches out of designing and building disconnect capabilities into a power system. One easy-to-install package solves several code and end-user requirements. This all-in-one power module provides selective coordination, remote shunt trip capability, built-in fire safety signal interface; electrical, mechanical and fire safety single point tie-in; component protection, high fault withstand, resistance to high in-rush current, and no annual calibration or testing to maintain the system’s integrity. Direct Info Number 269. Over-voltage Protection Phoenix Contact has introduced the Mains-Plugtrab, a DIN-rail mountable, 120V AC equipment power supply protector. Designed to protect sensitive control equipment from damage by external or internal transient voltage influences, it ensures your control system uptime and reliability. The device provides over-voltage protection from electrical transients caused by lightning, switching operations, utility actions, and de-energized inductive loads. It provides protection to power supplies, PLCs, PCs, controllers and other electrical equipment. Direct Info Number 270. Transient Detector Siemens Energy & Automation Inc. has introduced the Access 9500 power meter, a sophisticated power monitoring device that captures faults, outages, and transients by detecting subtle disturbances that could shut down a critical process. Customers are automatically notified of the disturbance and the information is recorded so that problems can be remedied quickly. Direct Info Number 271. Surge Protection Eaton’s Cutler-Hammer has introduced a loadcenter with built-in surge protection. The home electronic protection panel features a complete home surge protector (CHSP) integrated into a Type CH loadcenter. The exclusive design requires less wall space and is easier to install than loadcenters requiring add-on surge protection devices. The CHSP with a 70kA surge current rating provides a high level of protection for major appliances and sensitive electronic equipment such as computers, home office equipment, and entertainment systems. Direct Info Number 272. Power Protector Specialty Lighting’s PCH 646 comptroller unit protects office computers, monitors, printers, and other sensitive electrical devices against damaging voltage electrical surges, power spikes, and lightning strikes. It mounts readily into routed openings with side-mounted spring clips on the inside or outside panels of metal or wood desks, side returns, credenzas, or panel systems. Direct Info Number 273. Ultracapacitor PowerCache has the PC1000, a 1,200-farad ultracapacitor. It supplies power to a system during peak loads and outages. The device is ideal for hybrid electric vehicle, industrial, UPS, and fuel cell applications, or for any other application requiring pulsed power, high cycle reliability, and low maintenance. Direct Info Number 274. Uninterruptible Power Supplies Leviton Manufacturing Co. has added a line of uninterruptible power supplies (UPS) to its power quality product offering. It consists of single-phase, 115VAC line-interactive and off-line models. Smaller models provide a simulated sinewave output with larger models offering a pure sinewave option. Strip, traditional, tower-style, and low-profile models are available. Direct Info Number 275. Surge Protectors Intermatic’s PanelGuard surge protection devices come in a variety of models, but the premium models designed for heavy industry service entrances are able to withstand surges of up to 200,000A. When a device senses an increase in voltage, it reacts like an extremely fast switch, diverting the surge current associated with the event and suppressing the voltage, thereby shielding the electronic equipment that is fed from protected service entrance switchboard and downstream panelboards. Direct Info Number 276. Surge Protector ADSL (Asynchronous Digital Subscriber Line) technology now being used by the telecommunication industry to provide digital service is fully protected by the phone board provided as standard fare in Square D’s SurgeBreaker Plus. The improved technology means that customers will no longer need to purchase an additional module to protect their digital/analog phone service and equipment. The current analog phone board included with the protector has a clamping voltage compliant with the current telecom standards for both analog and digital signals associated with voice and ADSL service. Direct Info Number 277. Industrial UPS Solidstate Controls Inc. has a line of uninterruptible power supply (UPS) systems designed for the industrial market. The ProcessPower UPS product line is available in sizes ranging from 10-125kVA three-phase. The units are designed for use in process control applications such as power generation, petrochemical, pulp and paper, steelmaking, pharmaceutical, glass, and textiles. They can also be used in conjunction with new distributed control system installations. The UPS is a true, on-line, double-conversion system that provides clean, regulated, continuous power for critical AC loads. The line uses state-of-the-art PWM (pulse width modulation) technology incorporating high power IGBT semi-conductors. Direct Info Number 278. Surge Protectors Intermatic’s PanelGuard surge protection devices come in a variety of models, but the premium models designed for heavy industry service entrances are able to withstand surges of up to 200,000A. When a device senses an increase in voltage, it reacts like an extremely fast switch, diverting the surge current associated with the event and suppressing the voltage, thereby shielding the electronic equipment that is fed from protected service entrance switchboard and downstream panelboards. Direct Info Number 276. Surge Protector ADSL (Asynchronous Digital Subscriber Line) technology now being used by the telecommunication industry to provide digital service is fully protected by the phone board provided as standard fare in Square D’s SurgeBreaker Plus. The improved technology means that customers will no longer need to purchase an additional module to protect their digital/analog phone service and equipment. The current analog phone board included with the protector has a clamping voltage compliant with the current telecom standards for both analog and digital signals associated with voice and ADSL service. Direct Info Number 277. Industrial UPS Solidstate Controls Inc. has a line of uninterruptible power supply (UPS) systems designed for the industrial market. The ProcessPower UPS product line is available in sizes ranging from 10-125kVA three-phase. The units are designed for use in process control applications such as power generation, petrochemical, pulp and paper, steelmaking, pharmaceutical, glass, and textiles. They can also be used in conjunction with new distributed control system installations. The UPS is a true, on-line, double-conversion system that provides clean, regulated, continuous power for critical AC loads. The line uses state-of-the-art PWM (pulse width modulation) technology incorporating high power IGBT semi-conductors. Direct Info Number 278.

Advertisement

Advertisement

Advertisement

Advertisement

featured Video

;

3M - Science. Applied to Life.

Advertisement

Related Articles

Advertisement