Electrical conduit joining techniques vary by conduit type, and each approach offers unique benefits based on application needs. Here’s an overview of recommended methods for joining fiberglass conduit from Champion Fiberglass.

Advertisement

Advertisement

Advertisement

Advertisement

Advertisement

Electrical conduit joining techniques vary by conduit type, and each approach offers unique benefits based on application needs. Here’s an overview of recommended methods for joining fiberglass conduit:

Champion Duct®

Champion Duct® offers easy installation with high fire, corrosion and impact resistance for below-ground, concrete-encased and under-bridge applications. Here’s a breakdown of the joining options available:

Interference Joint

Ideal for below-ground concrete encasement, this method features a durable connection with the following characteristics:

  • Design: Bell and spigot with buttress-type male threads; belled end features female mating threads
  • Benefits: Tapered threads for a quick, simple assembly without the use of epoxy adhesive as well as a concrete-tight (not watertight) joint with 1,000 lbs. pull-out strength (adhesive not required)
  • Sizes available: IPS (2- to 8-in. diameters) and ID (2- to 6-in. diameters)
  • Additional applications and considerations: The interference joint connection can be used for above-ground installations when conduit sections are connected with epoxy adhesive to make a tight lock joint.
Watch video demonstration:

 


Gasket Joint (Triple Seal)

Best suited for direct burial and underground concrete embedment, the gasket joint ensures a secure fit with these features:

  • Design: Spigot and bell with a triple-seal gasket set into a permanent groove with interference joint
  • Benefits: Watertight, concrete-tight, with up to 2,000 lbs. pull-out strength; no threads needed for 500 lbs. pull-out strength
  • Sizes available: IPS (¾- to 8-in. diameters) and ID (2- to 6-in. diameters)
Watch video demonstration:

 


Tight Lock Joint

This permanent joint uses Champion Mix® epoxy adhesive for high-strength, watertight connections in both above and below-ground settings:

  • Design: Adhesive applied to the spigot end and inserted into the belled end for a tight seal
  • Benefits: Strong, water-tight joint connection
  • Sizes available: IPS and ID conduits 2 in. and above in SW, MW and HW epoxy resin
Watch video demonstration:

 


Champion Haz Duct® XW Type

Straight Socket Joint

The straight socket joint is versatile, suitable for various applications and compatible with Champion Duct SW, MW and HW conduits.

 

  • Design: Bell and spigot, with the spigot sliding easily into the belled end
  • Benefits: High pull-out strength, concrete and watertight with Champion Mix® epoxy adhesive
  • Sizes available: IPS ¾- to 1½-in. diameters*, ID 8- to 12-in. diameters** and XW conduits (all diameters)
  • Applications: Suits below-ground, direct-buried, concrete-encased, watertight joint, below-ground, concrete-encased and under-bridge or above-ground installations.

Champion Fiberglass® offers a range of joining solutions designed for reliable, durable connections across various installation environments.

Contact Champion Fiberglass

 

*Straight socket joint connection is available for sizes 2″ through 8″ upon request, otherwise interference joint is provided when available.